Skip to content
TENCANPLANETARY BALL MILLS

Iron-based foil: recorded D50 18.6 µm and D90 57.5 µm at fourteen hours.

Iron-based foil: recorded D50 18.6 µm and D90 57.5 µm at fourteen hours. Meet D50 = 16–20 µm and D90 = 70 µm as the recorded acceptance requirements.

Sample assessment

The feed was iron-based foil pieces. Composition, thickness and initial particle-size distribution were not supplied.

Analyst consideration: For foil, fragmentation and deformation can compete, making morphology important alongside both percentiles. The final median and tail together give a stronger physical endpoint than either one alone.

Recorded objective

Meet D50 = 16–20 µm and D90 = 70 µm as the recorded acceptance requirements.

Equipment and selection

The machine entry is XQM. TENCAN Vertical Planetary Ball Mill is associated at the recorded series level. No exact housing variant is inferred from jar capacity or an abbreviated machine label.

Test setup

Jar entryZirconia jar
Media entryZirconia balls
Media-charge notationStandard charge; individual specification not recorded
Sample-load entry25g
Controller speed setting400
Cycle notation5/1

Unlabelled jar, media and load numbers remain source notation, not assigned units. Controller settings are not certified rpm. The cycle notation has no independently stated timing unit or reversing definition.

Recorded procedure and results

The setup lists a zirconia jar and media with 25 g material. At thirty minutes little change was observed. After increasing the setting to 500, refinement began by 150 minutes. At 540 minutes the sample gave D50 = 71 µm and D90 = 167 µm. The setting then increased to 550; at fourteen hours the jar was hot and the sample gave D50 = 18.6 µm and D90 = 57.5 µm. The result is marked accepted.

Interpretation

The final D50 lies in the specified interval and D90 is below the recorded 70 µm ceiling. Neither percentile is an all-particle maximum, and the hot-jar observation remains relevant to process transfer.

Practical precautions

Confirm temperature limits and analytical preparation before repetition. Preserve the intermediate percentiles and inspect morphology rather than describing the final material only by its median.

TENCAN alternatives to evaluate

TENCAN Air-Cooled Planetary Ball Mill. Air assistance can be evaluated because the iron-based foil jar was hot at fourteen hours. Measure the sample temperature and retain both final percentiles when comparing cooled and uncooled charges. Air assistance addresses the observed hot jar by removing heat from the working area; a matched trial must still measure the powder temperature and morphology to assess whether that change is useful. This is an untested comparison proposal, not a result of this trial.

Association follows the explicit XQM source entry; only recorded tested series/configurations are related. No jar-volume inference.

About this trial

TENCAN laboratory trial, 2017–2020. Observations above come from this experimental record; selection considerations and proposed comparisons are engineering interpretation. Results apply to this sample and recorded conditions.

View all sample trials

YOUR MATERIAL.
YOUR NEXT TEST.

Share your starting material, target particle size and sample quantity with our engineers.

Discuss a sample trial

Discuss your project.

Tell us about your material, equipment or service needs.