Sample assessment
The fluororesin is identified only by its broad material class. A qualitative texture objective is recorded without an instrumental size criterion. The laboratory test record documents this preparation only; applying the method to another batch requires a matched trial.
Recorded objective
Process until the material no longer has a perceptible granular texture.
Equipment and selection
The recorded planetary machine is XQM. The corresponding TENCAN family is the Vertical Planetary Ball Mill. The jar volume identifies the test container and does not establish an exact machine variant or production capacity. Equipment association follows the recorded machine designation.
Test setup
| Recorded planetary machine | XQM |
|---|---|
| Documented setup | 250 mL zirconia jar with standard zirconia balls; 47 g coarse fluororesin powder; dry milling; speed setting 480. |
| Recorded operating cycle | Run 5 / pause 1; units not stated in mode field |
Speed values are reproduced as recorded settings. A rotational unit and planetary-disc versus jar-speed basis are not stated, so these numbers are not labelled rpm.
Recorded procedure and results
After 2.5 hours, the record states that no granular feel remained and the material was removed. No numerical particle-size distribution, temperature, chemical identity beyond fluororesin or instrumental texture measurement is supplied.
Interpretation
The recorded qualitative texture criterion was observed at the endpoint. This does not justify assigning a micron value or identifying the resin as a particular fluoropolymer. It is a documented feasibility observation for the supplied material.
Practical precautions
Use an agreed, contained observation method and define how the texture criterion will be judged. Identify the resin grade and measure temperature before transferring the method, and add instrumental size data when a numerical preparation specification is required.
TENCAN alternatives to evaluate
For follow-up comparison, consider the TENCAN Omnidirectional Planetary Ball Mill. For fluororesin, a matched QXQM trial can test whether changing orientation affects the fluororesin texture endpoint with a defined quantitative check. Keep sample mass, media and sampling times controlled. This is a proposed comparison; the test record does not demonstrate a superior result for that alternative. Confirm jar compatibility and the permitted complete loaded mass before selecting a configuration.
Procedure records XQM; related product is the corresponding tested machine family. Exact variant is not inferred from jar size.
About this trial
TENCAN laboratory trial, 2025. Observations above come from this experimental record; selection considerations and proposed comparisons are engineering interpretation. Results apply to this sample and recorded conditions.